The Clipsal MAX9 MX9R31 range of SLIM RCBOs combines C curve overcurrent protection with 30mA Type A earth leakage protection in a single 1P+N device. It is available in 6A, 10A, 16A, 20A, 25A and 32A ratings.

Each RCBO is only 18mm (one module) wide, with a 6kA breaking capacity, active and neutral switching and top or bottom line connection. The range suits MAXBAR, and fits the MAX9 PRO chassis as well as DIN rail.

Key Features

  • Wide Rating Choice – Available in 6A, 10A, 16A, 20A, 25A and 32A, each combining C curve overcurrent and 30mA earth leakage protection in one 1P+N device.
  • 30mA Type A Sensitivity – Type A RCD senses AC as well as pulsating DC earth leakage currents.
  • 6kA Breaking Capacity – 6000A rated breaking capacity at 240V AC, limitation class 3.
  • Active and Neutral Switching – Switches both the active and neutral contacts.
  • Compact SLIM Module – Only 18mm (one module) wide, so more RCDs and MCBs fit in the one enclosure.
  • Top or Bottom Connection – Line connection can be made from the top or bottom.
  • MAXBAR Compatible – MAXBAR distributes both active and neutral to the RCBO, so no feed cables are needed.
  • MAX9 PRO Chassis Compatible – Fits the MAX9 PRO phase neutral chassis as well as DIN rail, with no line side neutral cabling needed.
  • Combination Head Screws – Compatible with multiple types of screwdriver.
  • Trip Free Mechanism – ON/OFF locking with a trip free mechanism, plus a positive contact indicator on the toggle.
  • Lockable and Sealable – Through hole for sealing by wire, and compatible with the 26970 padlocking device for MAX9 SLIM RCBOs.

Specifications

  • Model: MX9R31
  • Range: Clipsal MAX9 SLIM
  • Poles: 1P+N (1 protected pole)
  • Available Ratings: 6A, 10A, 16A, 20A, 25A and 32A
  • Rated Voltage: 240V AC, 50/60Hz
  • Tripping Curve: C
  • Earth Leakage Sensitivity: 30mA
  • RCD Type: Type A
  • Earth Leakage Tripping: Instantaneous
  • Breaking Capacity: 6kA (6000A Icn)
  • Limitation Class: 3
  • Rated Impulse Withstand Voltage: 4kV
  • Terminals: Tunnel type, top: 1–16mm² rigid or 1–10mm² flexible; bottom: 1–10mm² rigid or 1–6mm² flexible (6A rating: 1–16mm² rigid or 1–10mm² flexible)
  • Mounting: MAX9 PRO chassis or DIN rail; MAXBAR compatible
  • Width: 1 module (18mm)
  • Dimensions: 93 × 18 × 73mm (H × W × D)
  • IP Rating: IP20

Applications

  • Per-circuit RCBO protection for lighting and power final sub-circuits
  • Light commercial and large residential switchboards
  • MAX9 PRO chassis and MAXBAR boards
  • Compact MAX9 switchboards where space is tight

Across 6A, 10A, 16A, 20A, 25A and 32A, the Clipsal MAX9 MX9R31 range offers 30mA Type A earth leakage protection, C curve overcurrent protection and a 6kA breaking capacity, a flexible choice for per-circuit protection in MAX9 switchboards.

Q. What ratings are available in the Clipsal MX9R31 range?
A.
The Clipsal MX9R31 range comes in 6A, 10A, 16A, 20A, 25A and 32A: 6A (MX9R3106), 10A (MX9R3110), 16A (MX9R3116), 20A (MX9R3120), 25A (MX9R3125) and 32A (MX9R3132). All are C curve, 30mA Type A, 1P+N RCBOs with a 6kA breaking capacity.

Q. What cable sizes do the Clipsal MX9R31 range terminals take?
A.
The MX9R31 range uses tunnel terminals taking top: 1–16mm² rigid or 1–10mm² flexible; bottom: 1–10mm² rigid or 1–6mm² flexible (6A rating: 1–16mm² rigid or 1–10mm² flexible) cable.

Q. Can the Clipsal MX9R31 range be used on a MAX9 PRO chassis?
A.
Yes. Clipsal lists the MX9R31 range for the MAX9 PRO chassis as well as DIN rail, and it suits MAXBAR, which feeds both active and neutral to each RCBO without feed cables.

Q. What is the difference between the Clipsal MX9R31 and MX9R11 ranges?
A.
Both are C curve, 6kA, Type A, 18mm MAX9 SLIM RCBOs. The MX9R31 range has 30mA earth leakage sensitivity, while the MX9R11 range has 10mA sensitivity.

All products must be installed by a licensed electrican. DIY electrical work is illegal and very dangerous.

Change of Mind
All products purchased from MJS Electrical Products & Supplies are backed by a thirty (30) day Peace of Mind Return Policy. All products returned must be in perfect unused condition, with all components, complete with original packaging. We will not allow returns on damaged or incomplete products. Proof of purchase is required. Should the product not be in original condition, please contact us before returning it as this may save you some unnecessary costs.

Damaged / Faulty Goods
If you find that the goods were damaged in transit or were faulty in some manner, please contact us within 24 hours of receiving the goods. We will organise for the return of the goods and arrange a credit towards your next purchase or send a replacement product. Customer will incur the cost of return postage and be credited the purchase price only. We recommend that you return your unwanted items using registered post or trackable courier. We can not be held responsible if returned items are lost in transit.

Warranties
Product warranties are governed by the respective manufacturers and / or suppliers warranty terms and conditions (available on request). We will not be liable to you or any third party for any loss suffered due to product failure. We will process product warranty claims through the respective manufacturers and/or suppliers. All warranties are void if the product is not installed by a licensed electrician.

Type RCBO
Voltage 240V AC
Frequency 50Hz/60Hz
Poles 1P+N
Range Clipsal MAX9
Trip Curve C Curve
kA Rating 6kA
Earth Leakage Protection Class Type A
Earth Leakage Sensitivity 30mA
PRODUCT INFO
SKU CLMX9R31
Model # MX9R31
Brand Clipsal
SHIPPING INFO
Shipping Weight 0.1360kg
Shipping Width 0.098m
Shipping Height 0.077m
Shipping Length 0.012m