The Red Smoke Alarms Relay Base (Model: RRB) is a specialized accessory designed to enhance the functionality of Red's mains-powered smoke alarms. This relay base facilitates integration with auxiliary devices, such as lights and sirens, providing a comprehensive safety solution for residential and commercial environments.

Key Features:

  • Auxiliary Device Integration: Equipped with voltage-free relay contacts (NO/COM/NC), the RRB allows connection to external devices like lights, sirens, or building management systems, enabling coordinated responses during alarm events.
  • Configurable Relay Operation: The relay can be set to activate only when the local alarm detects smoke or when any interconnected alarm is triggered, offering flexibility to meet specific safety requirements.
  • Compatibility: Designed exclusively for use with Red Smoke Alarm models R240 and R240RC, ensuring seamless integration and reliable performance.
  • Robust Design: Constructed to meet rigorous safety standards, the RRB relay base ensures long-lasting durability and dependable operation.

Specifications:

  • Model Number: RRB
  • Power Source: 220-240V AC, 50Hz
  • Operating Current: ≤40 mA
  • Relay Contacts Rating: 250V AC, 2A
  • Operating Temperature Range: 0°C to 45°C
  • Humidity Range: 5% to 95%
  • Terminals: Active (A), Neutral (N), Earth/Loop (E/Loop), Interconnect (I)
  • Interconnection Capability: Supports hardwired interconnection of up to 40 Red smoke alarms within a 150-meter range

Applications:

  • Enhanced Safety Systems: Ideal for integrating smoke alarms with additional warning devices, such as visual indicators or external sirens, to assist occupants with hearing impairments or in noisy environments.
  • Building Management Integration: Facilitates connection to building management or automation systems, enabling centralized monitoring and control of fire safety devices.
  • Customizable Alarm Responses: Allows for tailored responses, such as activating emergency lighting or unlocking exit doors when an alarm is triggered, enhancing overall safety measures.

Incorporating the Red Smoke Alarms Relay Base (RRB) into your safety system enables seamless integration with auxiliary devices, providing a comprehensive and responsive solution to fire detection and alarm requirements.

Q: Can the RRB relay base be used with smoke alarm models from other manufacturers?
A: No, the RRB is specifically designed for compatibility with Red Smoke Alarm models R240 and R240RC and is not compatible with third-party products, systems, or fire panels.

Q: Is it possible to interconnect multiple RRB relay bases?
A: Yes, up to 40 Red smoke alarms equipped with RRB relay bases can be hardwired and interconnected within a 150-meter range, allowing for synchronized operation across all devices.

Q: Does the RRB relay base require a separate power supply?
A: No, the RRB operates on the same 220-240V AC mains power supply as the connected smoke alarm, eliminating the need for an additional power source.

Q: What types of auxiliary devices can be connected to the RRB relay base?
A:
The voltage-free relay contacts (NO/COM/NC) allow for the connection of various auxiliary devices, such as external sirens, strobe lights, or integration with building management systems, enhancing the alarm system's functionality.

All products must be installed by a licensed electrican. DIY electrical work is illegal and very dangerous.

Change of Mind
All products purchased from MJS Electrical Products & Supplies are backed by a thirty (30) day Peace of Mind Return Policy. All products returned must be in perfect unused condition, with all components, complete with original packaging. We will not allow returns on damaged or incomplete products. Proof of purchase is required. Should the product not be in original condition, please contact us before returning it as this may save you some unnecessary costs.

Damaged / Faulty Goods
If you find that the goods were damaged in transit or were faulty in some manner, please contact us within 24 hours of receiving the goods. We will organise for the return of the goods and arrange a credit towards your next purchase or send a replacement product. Customer will incur the cost of return postage and be credited the purchase price only. We recommend that you return your unwanted items using registered post or trackable courier. We can not be held responsible if returned items are lost in transit.

Warranties
Product warranties are governed by the respective manufacturers and / or suppliers warranty terms and conditions (available on request). We will not be liable to you or any third party for any loss suffered due to product failure. We will process product warranty claims through the respective manufacturers and/or suppliers. All warranties are void if the product is not installed by a licensed electrician.

PRODUCT INFO
SKU REDRRB
Model # RRB
Barcode # 9358418000022
SHIPPING INFO
Shipping Weight 0.1420kg
Shipping Width 0.145m
Shipping Height 0.130m
Shipping Length 0.145m